Data sheet
Download vehicle data as a PDF
The data sheet is generated automatically from the current information on this vehicle page.
Product data: 05.11.2026
Conversion specification
Base vehicle: panel van, front-wheel drive, sliding door on the right, internal combustion engine (ICE)
Delivery code: 17030
The Kerstner chilled goods conversion for the Renault Master combines the highest insulation performance with consistent practicality – developed and manufactured for everyday use in food and chilled goods transport.
The conversion achieves a K coefficient of below 0.4 W/m²K and is classified as “heavily insulated” under ATP requirements. This is made possible by the seamless connection of all insulation elements – including at the sliding door – without gaps or thermal bridges.
The engine-driven refrigeration system reliably maintains the temperature range from 0 °C to -20°C throughout the journey.
The polyurethane insulation components are water-repellent, antibacterial and impact-resistant, and meet the requirements of the ATP and HACCP guidelines. The easy-to-clean surface reduces the effort required to maintain hygiene in day-to-day operation.
Thanks to its computer-optimised fit, the conversion provides a usable load volume of 7 – 8.5 m³ with unobstructed clearance between the wheel arches, suitable for loading Euro pallets.
Variants and load space
L2H2 (7.0m3)
front-wheel drive, 3583 mm
| Wheelbase | 3583 mm |
|---|---|
| Load compartment length | 2850 mm |
| Width between wheel arches | 1270 mm |
| Upper width | 1650 mm |
| Interior height | 1630 mm |
| Evaporator height | 100 mm |
| Load volume | 7,0 m³ |
| Euro pallets | 3-4 |
| Compatible refrigeration units | CoolJet C206RC / Thermo King V300 max 20 / Thermo King V300 max 50 / Thermo King V300 max 50 Spectrum / Thermo King V200 max 50 / Thermo King V200 max 20 / Thermo King V400X Max 20 / Thermo King V400X Max 50 |
L3H2 (8.5m3)
front-wheel drive, 4213 mm
| Wheelbase | 4213 mm |
|---|---|
| Load compartment length | 3480 mm |
| Width between wheel arches | 1270 mm |
| Upper width | 1650 mm |
| Interior height | 1690 mm |
| Evaporator height | 100 mm |
| Load volume | 8,5 m³ |
| Euro pallets | 4-5 |
| Compatible refrigeration units | Thermo King V300-20 / Thermo King V200 max 50 / Thermo King V200 max 20 / Thermo King V400X Max 20 / Thermo King V400X Max 50 |
Refrigeration
Temperature range: on request
CoolJet C206RC
Roof-mounted · Stationary refrigeration: required
The CoolJet C206RC is a roof-mounted refrigeration unit with belt drive designed for deep-freeze transport.
Application: frozen goods transport
Type: roof-mounted unit
Refrigeration capacity: max. 3100W at 0°C
Operating voltage: 12 V
Max. current draw: 25 A
Airflow: 1227m³/h
Refrigerant: R452A
Installation height: +250mm
Thermo King V300 max 20
External · Stationary refrigeration: included
– Engine-driven transport refrigeration unit for cooling, 12 V
– Ultra-flat ES150 evaporator
– Split unit for installation on the front wall above the cab
– Refrigeration while driving, 12 V (driven by the vehicle engine), and 220 V electric motor
– Ultra-flat ES 300 evaporator with 2 fans, airflow 1250 m³/h
– Manual defrost or automatic timer-controlled defrost
– In-cab remote control with temperature display
The remote control and temperature recorder are installed in the existing
available DIN slot. Otherwise, they are installed at a location
we consider suitable. Subsequent changes can be made
and will be charged according to the work required.
– DSR controller – Smart Reefer
– Effective refrigeration capacity at an ambient temperature of 30 °C under ATP conditions:
3355 Watt at 0 °C
1820 Watt at -20 °C
1550 Watt at -25 °C
– R452A refrigerant: particularly environmentally friendly – 50% lower CO² impact; complies with legal requirements from 2020
Application: frozen goods transport
Type: roof-mounted unit
Refrigeration capacity: max. 3330W at 0°C
Operating voltage: 12V
Max. current draw: 452 A
Airflow: 1400 m³/h
Refrigerant: R452A
Installation height: approx. 221 mm
Thermo King V300 max 50
External · Stationary refrigeration: included
– Engine-driven transport refrigeration unit for cooling and heating
– Split unit for installation on the front wall above the cab
– Refrigeration while driving, 12 V (driven by the vehicle engine), and 220 V electric motor
– Ultra-flat ES 300 evaporator with 2 fans, airflow 1250 m³/h
– Manual defrost or automatic timer-controlled defrost
– In-cab remote control with temperature display
The remote control and temperature recorder are installed in the existing available DIN slot. Otherwise, they are installed at a location we consider suitable.
Subsequent changes can be made and will be charged according to the work required.
– DSR controller – Smart Reefer
– Effective refrigeration capacity at an ambient temperature of 30 °C under ATP conditions:
3355 Watt at 0 °C
1820 Watt at -20 °C
1550 Watt at -25 °C
Application: chilled and frozen goods transport
Type: roof-mounted unit
Refrigeration capacity: max. 3330W at 0°C
Operating voltage: 12V
Max. current draw: 452 A
Airflow: 1400 m³/h
Refrigerant: R452A
Installation height: +221 mm
Note: &
Thermo King V300 max 50 Spectrum
External · Stationary refrigeration: included
– For vehicles with two temperature zones separated by a transverse partition
– Split unit for installation on the front wall above the cab
with two ES 150 evaporators
– Refrigeration while driving, 12V (driven by the vehicle engine)
– Stationary / overnight refrigeration (220V electric motor)
– Fully automatic temperature control with heating in the chilled goods compartment
– Manual defrost or automatic timer-controlled defrost
– In-cab remote control with two thermostats
The remote control and temperature recorder are installed in the existing available DIN slot. Otherwise, they are installed at a location we consider suitable.
Subsequent changes can be made and will be charged according to the work required.
– MTC dual-temperature module
– DSR controller – Smart Reefer
– Effective refrigeration capacity at an ambient temperature of 30 °C under ATP conditions:
Per evaporator: approx. 2500 Watt at 0 °C
Approx. 1100 Watt at -20 °C
– Total heating capacity (conditions: +18 °C/-18 °C): 3100 Watt
– R452A refrigerant: particularly environmentally friendly – 50% lower CO2 impact; complies with legal requirements from 2020
Application: chilled and frozen goods transport
Type: roof-mounted
Refrigeration capacity: 1880 Watt at -20°C
Operating voltage: 12 V
Max. current draw: 452 A
Airflow: 2x 890 m³/h
Refrigerant: R452a
Installation height: +221mm
Note: & roof
Thermo King V300-20
Roof-mounted · Stationary refrigeration: included
– Engine-driven transport refrigeration unit for cooling
– Split unit for installation on the front wall above the cab
– Refrigeration while driving, 12 V (driven by the vehicle engine), and 220 V electric motor
– Ultra-flat ES 300 evaporator with 2 fans, airflow 1400 m³/h
– Manual defrost or automatic timer-controlled defrost
– In-cab remote control with temperature display
The remote control and temperature recorder are installed in the existing available DIN slot. Otherwise, they are installed at a location we consider suitable.
Subsequent changes can be made and will be charged according to the work required.
– DSR controller – Smart Reefer
– Effective refrigeration capacity at an ambient temperature of 30 °C under ATP conditions:
2965 Watt at 0 °C
Application: chilled goods transport
Type: roof-mounted unit
Refrigeration capacity: 2965 at 0°C
Operating voltage: 12V
Max. current draw: 134 A
Airflow: 2033 m³/h
Refrigerant: R134a
Installation height: +222 mm
Thermo King V200 max 50
External · Stationary refrigeration: included
– Split refrigeration unit for installation on the front wall or roof
– Ultra-flat ES 200 evaporator with 2 fans, airflow 1070 m³/h
– In-transit cooling at 12 V (driven by the vehicle engine) and 230 V electric motor
– Manual defrost or automatic timer-controlled defrost
– In-cab remote control with temperature display
The remote control and temperature recorder are installed in the existing
available DIN slot. Otherwise, they are installed at a location
we consider suitable. Subsequent changes can be made
and will be charged according to the work required.
– DSR controller – Smart Reefer
– Effective refrigeration capacity at an ambient temperature of 30 °C under ATP conditions:
2710 W at 0 °C
1560 W at -20 °C
1190 W at -25 °C
– Heating capacity approx. 2400 W
945 W at -20 °C
– R452A refrigerant: particularly environmentally friendly – 50% lower CO² impact; complies with legal requirements from 2020
Application: chilled and frozen goods transport
Type: roof-mounted
Cooling capacity: 2710 W at 0 °C
Operating voltage: 12V
Max. current draw: 452 A
Air flow: 1070 m³/h
Refrigerant: R452A
Installation height: +221mm
Note: & roof
Thermo King V200 max 20
External · Stationary refrigeration: included
– Split refrigeration unit for installation on the front wall or roof
– Ultra-flat ES 200 evaporator with 2 fans, airflow 1070 m³/h
– In-transit cooling at 12 V (driven by the vehicle engine) and 230 V electric motor
– Manual defrost or automatic timer-controlled defrost
– In-cab remote control with temperature display
The remote control and temperature recorder are installed in the existing
available DIN slot. Otherwise, they are installed at a location
we consider suitable. Subsequent changes can be made
and will be charged according to the work required.
– DSR controller – Smart Reefer
– Effective refrigeration capacity at an ambient temperature of 30 °C under ATP conditions:
2710 W at 0 °C
1560 W at -20 °C
1190 W at -25 °C
– R452A refrigerant: particularly environmentally friendly – 50% lower CO² impact; complies with legal requirements from 2020
Application: chilled and frozen goods transport
Type: roof-mounted
Cooling capacity: 2710 W at 0 °C
Operating voltage: 12V
Max. current draw: 452 A
Air flow: 1070 m³/h
Refrigerant: R452A
Installation height: +221mm
Note: & roof
Thermo King V400X Max 20
Roof-mounted · Stationary refrigeration: included
Thermo King V-400X MAX: powerful and quiet refrigeration unit without its own engine and without exhaust emissions. The temperature is precisely regulated to 1 °C, with standby cooling possible via mains power
The Thermo King V-400X MAX from the VX series offers high cooling capacity and precise temperature control. Using the control panel in the driver's cab, you regulate the load space temperature in single and multi-temperature operation to an accuracy of 1 °C.
Since the unit operates without its own motor, it produces no emissions and runs particularly quietly. This is an advantage for deliveries in city centers and residential areas.
The device weighs only 75 kg (model 50) and is compactly built, leaving more payload capacity for the cargo. The aerodynamic design is optimized for daily use.
– Cooling capacity during driving: 4.082 W at 0 °C / 2.237 W at -20 °C
– Cooling capacity during mains operation: 3.026 W at 0 °C / 1.496 W at -20 °C
– Airflow volume: 1.990 m³/h
– Temperature control: Single and multi-temperature, accurate to 1 °C
– Operation: Operating panel inside the driver's cab
Application: Fresh delivery and deep-freeze
Type: roof-mounted unit
Cooling capacity: 4082 watts
Operating voltage: 12V
Max. current draw: 452 A
Air flow: 1990m³
Refrigerant: R452a
Installation height: +273 mm
Note: driving and standby refrigeration
Thermo King V400X Max 50
Roof-mounted · Stationary refrigeration: included
The V-400X MAX from Thermo King's VX series is powered by the vehicle's engine and requires no separate motor. This ensures quiet operation with minimal vibrations and no exhaust emissions, making it ideal for deliveries in city centers and low-emission zones, including at night.
With a cooling capacity of 4.082 W at 0 °C and 2.240 W at −20 °C, this unit is suitable for both fresh delivery and deep-freeze transport. The cab controller Direct Smart Reefer (DSR III) maintains the cargo area temperature within ±1 °C. It displays malfunctions via clear alarm codes and automatically reminds of scheduled maintenance.
The 50 version offers two additional features: through electric standby, the unit continues cooling when the engine is off using an external power supply at 400 V. The heating function protects the cargo in winter from excessively low temperatures.
The lightweight, aerodynamic housing preserves payload capacity. The condenser can be mounted on the front wall, on the roof, or recessed into the roof. Defrosting is automatic via hot gas.
Optional equipment includes door switches, a DIN adapter for installing the controller in the radio slot, telematics via BlueBox Lite, and data loggers compliant with EN 12830. The max 50 version offers: cooling during transit, cooling while stationary via external 400V power connection, as well as a heating function with 3.564W during driving operation, and 1841W during mains operation.
Application area: fresh delivery / deep-freeze
Type: roof-mounted unit
Cooling capacity: 4.082W during transit
Operating voltage: 12V
Maximum current: 36A
Air flow: 1.990 m³/h
Refrigerant: R452a
Unit height: +273mm
Standard equipment
- Kerstner easyfit insulation (K coefficient =0.37)
- Engine-driven refrigeration system for refrigeration while driving and stationary
- PU floor with anti-slip coating and water-retaining sill at the sliding door
- Aluminium impact protection (approx. 20 cm high) on the left, right (except sliding door) and front wall
- Horizontal half-round lashing rails above the wheel arches on the left and right
- LED interior light
- Emergency release for rear doors
- 2 water drains
Vehicle codes
Required codes4 items
- RFBT – Heavy-duty battery
- EMRD4 – Conversion criterion 4
- WIADA – 2-pole electrical interface for conversions, 12V-24A each
- PWTKE – For manual transmission: engine power take-off (not for automatic transmission)
Excluded codes7 items
- TWBPW – Towbar – for underfloor unit
- SPTYO – Spare wheel – for underfloor unit
- PCU.. – Load compartment protection packages
- PCK40 – Complete POLYPRO load compartment protection package
- RRWFL – Wooden floor in load compartment
- ICTF3 – Polypropylene side lining
- LSLNW – Left sliding door
Equipment and accessories
Required accessories
Partially recessed roof unit
Required accessories · Suitable for: L2H2 (7,0m3) / CoolJet C206RC; L2H2 (7,0m3) / Thermo King V300 max 20; L2H2 (7,0m3) / Thermo King V300 max 50; L2H2 (7,0m3) / Thermo King V300 max 50 Spectrum; L2H2 (7,0m3) / Thermo King V200 max 50; L2H2 (7,0m3) / Thermo King V200 max 20; L2H2 (7,0m3) / Thermo King V400X Max 20; L2H2 (7,0m3) / Thermo King V400X Max 50; L3H2 (8,5m3) / Thermo King V300-20; L3H2 (8,5m3) / Thermo King V200 max 50; L3H2 (8,5m3) / Thermo King V200 max 20; L3H2 (8,5m3) / Thermo King V400X Max 20; L3H2 (8,5m3) / Thermo King V400X Max 50
Quantity: Default 1, Minimum 1 piece
TÜV assessment / Stage II certificate of conformity (COC)
Required accessories · Suitable for: L2H2 (7,0m3) / CoolJet C206RC; L2H2 (7,0m3) / Thermo King V300 max 20; L2H2 (7,0m3) / Thermo King V300 max 50; L2H2 (7,0m3) / Thermo King V300 max 50 Spectrum; L2H2 (7,0m3) / Thermo King V200 max 50; L2H2 (7,0m3) / Thermo King V200 max 20; L2H2 (7,0m3) / Thermo King V400X Max 20; L2H2 (7,0m3) / Thermo King V400X Max 50; L3H2 (8,5m3) / Thermo King V300-20; L3H2 (8,5m3) / Thermo King V200 max 50; L3H2 (8,5m3) / Thermo King V200 max 20; L3H2 (8,5m3) / Thermo King V400X Max 20; L3H2 (8,5m3) / Thermo King V400X Max 50
Required for submission at registration Quantity: Default 1, Minimum 1 piece
230 V standby cooling, frozen transport variant
Required accessories · Suitable for: L2H2 (7.0m3) / CoolJet C206RC
Optional accessories
Aluminium floor panel L2
Optional · Suitable for: L2H2 (7,0m3) / CoolJet C206RC; L2H2 (7,0m3) / Thermo King V300 max 20; L2H2 (7,0m3) / Thermo King V300 max 50; L2H2 (7,0m3) / Thermo King V300 max 50 Spectrum; L2H2 (7,0m3) / Thermo King V200 max 50; L2H2 (7,0m3) / Thermo King V200 max 20; L2H2 (7,0m3) / Thermo King V400X Max 20; L2H2 (7,0m3) / Thermo King V400X Max 50
Quantity: Default 1, Minimum 1 piece
Aluminium floor panel L3
Optional · Suitable for: L3H2 (8,5m3) / Thermo King V300-20; L3H2 (8,5m3) / Thermo King V200 max 50; L3H2 (8,5m3) / Thermo King V200 max 20; L3H2 (8,5m3) / Thermo King V400X Max 20; L3H2 (8,5m3) / Thermo King V400X Max 50
Quantity: Default 1, Minimum 1 piece
Non-slip load floor mat L2
Optional · Suitable for: L2H2 (7,0m3) / CoolJet C206RC; L2H2 (7,0m3) / Thermo King V300 max 20; L2H2 (7,0m3) / Thermo King V300 max 50; L2H2 (7,0m3) / Thermo King V300 max 50 Spectrum; L2H2 (7,0m3) / Thermo King V200 max 50; L2H2 (7,0m3) / Thermo King V200 max 20; L2H2 (7,0m3) / Thermo King V400X Max 20; L2H2 (7,0m3) / Thermo King V400X Max 50
Quantity: Default 1, Minimum 1 piece
Non-slip load floor mat L3
Optional · Suitable for: L3H2 (8,5m3) / Thermo King V300-20; L3H2 (8,5m3) / Thermo King V200 max 50; L3H2 (8,5m3) / Thermo King V200 max 20; L3H2 (8,5m3) / Thermo King V400X Max 20; L3H2 (8,5m3) / Thermo King V400X Max 50
Quantity: Default 1, Minimum 1 piece
Non-slip mat for shelf
Optional · Suitable for: L2H2 (7,0m3) / CoolJet C206RC; L2H2 (7,0m3) / Thermo King V300 max 20; L2H2 (7,0m3) / Thermo King V300 max 50; L2H2 (7,0m3) / Thermo King V300 max 50 Spectrum; L2H2 (7,0m3) / Thermo King V200 max 50; L2H2 (7,0m3) / Thermo King V200 max 20; L2H2 (7,0m3) / Thermo King V400X Max 20; L2H2 (7,0m3) / Thermo King V400X Max 50; L3H2 (8,5m3) / Thermo King V300-20; L3H2 (8,5m3) / Thermo King V200 max 50; L3H2 (8,5m3) / Thermo King V200 max 20; L3H2 (8,5m3) / Thermo King V400X Max 20; L3H2 (8,5m3) / Thermo King V400X Max 50
Quantity: Default 1, Minimum 1 piece
Shelf set I (1 shelf)
Optional · Suitable for: L2H2 (7,0m3) / CoolJet C206RC; L2H2 (7,0m3) / Thermo King V300 max 20; L2H2 (7,0m3) / Thermo King V300 max 50; L2H2 (7,0m3) / Thermo King V300 max 50 Spectrum; L2H2 (7,0m3) / Thermo King V200 max 50; L2H2 (7,0m3) / Thermo King V200 max 20; L2H2 (7,0m3) / Thermo King V400X Max 20; L2H2 (7,0m3) / Thermo King V400X Max 50; L3H2 (8,5m3) / Thermo King V300-20; L3H2 (8,5m3) / Thermo King V200 max 50; L3H2 (8,5m3) / Thermo King V200 max 20; L3H2 (8,5m3) / Thermo King V400X Max 20; L3H2 (8,5m3) / Thermo King V400X Max 50
Quantity: Default 1, Minimum 1 piece
Shelf set II (2 shelves one above the other)
Optional · Suitable for: L2H2 (7,0m3) / CoolJet C206RC; L2H2 (7,0m3) / Thermo King V300 max 20; L2H2 (7,0m3) / Thermo King V300 max 50; L2H2 (7,0m3) / Thermo King V300 max 50 Spectrum; L2H2 (7,0m3) / Thermo King V200 max 50; L2H2 (7,0m3) / Thermo King V200 max 20; L2H2 (7,0m3) / Thermo King V400X Max 20; L2H2 (7,0m3) / Thermo King V400X Max 50; L3H2 (8,5m3) / Thermo King V300-20; L3H2 (8,5m3) / Thermo King V200 max 50; L3H2 (8,5m3) / Thermo King V200 max 20; L3H2 (8,5m3) / Thermo King V400X Max 20; L3H2 (8,5m3) / Thermo King V400X Max 50
Quantity: Default 1, Minimum 1 piece
PVC strip curtain for the rear opening
Optional · Suitable for: L2H2 (7,0m3) / CoolJet C206RC; L2H2 (7,0m3) / Thermo King V300 max 20; L2H2 (7,0m3) / Thermo King V300 max 50; L2H2 (7,0m3) / Thermo King V300 max 50 Spectrum; L2H2 (7,0m3) / Thermo King V200 max 50; L2H2 (7,0m3) / Thermo King V200 max 20; L2H2 (7,0m3) / Thermo King V400X Max 20; L2H2 (7,0m3) / Thermo King V400X Max 50; L3H2 (8,5m3) / Thermo King V300-20; L3H2 (8,5m3) / Thermo King V200 max 50; L3H2 (8,5m3) / Thermo King V200 max 20; L3H2 (8,5m3) / Thermo King V400X Max 20; L3H2 (8,5m3) / Thermo King V400X Max 50
Quantity: Default 1, Minimum 1 piece
PVC strip curtain for the sliding door
Optional · Suitable for: L2H2 (7,0m3) / CoolJet C206RC; L2H2 (7,0m3) / Thermo King V300 max 20; L2H2 (7,0m3) / Thermo King V300 max 50; L2H2 (7,0m3) / Thermo King V300 max 50 Spectrum; L2H2 (7,0m3) / Thermo King V200 max 50; L2H2 (7,0m3) / Thermo King V200 max 20; L2H2 (7,0m3) / Thermo King V400X Max 20; L2H2 (7,0m3) / Thermo King V400X Max 50; L3H2 (8,5m3) / Thermo King V300-20; L3H2 (8,5m3) / Thermo King V200 max 50; L3H2 (8,5m3) / Thermo King V200 max 20; L3H2 (8,5m3) / Thermo King V400X Max 20; L3H2 (8,5m3) / Thermo King V400X Max 50
Quantity: Default 1, Minimum 1 piece
Additional horizontal lashing rails on the left and right L2
Optional · Suitable for: L2H2 (7,0m3) / CoolJet C206RC; L2H2 (7,0m3) / Thermo King V300 max 20; L2H2 (7,0m3) / Thermo King V300 max 50; L2H2 (7,0m3) / Thermo King V300 max 50 Spectrum; L2H2 (7,0m3) / Thermo King V200 max 50; L2H2 (7,0m3) / Thermo King V200 max 20; L2H2 (7,0m3) / Thermo King V400X Max 20; L2H2 (7,0m3) / Thermo King V400X Max 50
Quantity: Default 1, Minimum 1 piece
Additional horizontal lashing rails on the left and right L3
Optional · Suitable for: L3H2 (8,5m3) / Thermo King V300-20; L3H2 (8,5m3) / Thermo King V200 max 50; L3H2 (8,5m3) / Thermo King V200 max 20; L3H2 (8,5m3) / Thermo King V400X Max 20; L3H2 (8,5m3) / Thermo King V400X Max 50
Quantity: Default 1, Minimum 1 piece
Front-wall lashing rail
Optional · Suitable for: L2H2 (7,0m3) / CoolJet C206RC; L2H2 (7,0m3) / Thermo King V300 max 20; L2H2 (7,0m3) / Thermo King V300 max 50; L2H2 (7,0m3) / Thermo King V300 max 50 Spectrum; L2H2 (7,0m3) / Thermo King V200 max 50; L2H2 (7,0m3) / Thermo King V200 max 20; L2H2 (7,0m3) / Thermo King V400X Max 20; L2H2 (7,0m3) / Thermo King V400X Max 50; L3H2 (8,5m3) / Thermo King V300-20; L3H2 (8,5m3) / Thermo King V200 max 50; L3H2 (8,5m3) / Thermo King V200 max 20; L3H2 (8,5m3) / Thermo King V400X Max 20; L3H2 (8,5m3) / Thermo King V400X Max 50
Quantity: Default 1, Minimum 1 piece
ATP certificate FRCX
Optional · Suitable for: L2H2 (7,0m3) / CoolJet C206RC; L2H2 (7,0m3) / Thermo King V300 max 20; L2H2 (7,0m3) / Thermo King V300 max 50; L2H2 (7,0m3) / Thermo King V300 max 50 Spectrum; L2H2 (7,0m3) / Thermo King V200 max 50; L2H2 (7,0m3) / Thermo King V200 max 20; L2H2 (7,0m3) / Thermo King V400X Max 20; L2H2 (7,0m3) / Thermo King V400X Max 50; L3H2 (8,5m3) / Thermo King V300-20; L3H2 (8,5m3) / Thermo King V200 max 50; L3H2 (8,5m3) / Thermo King V200 max 20; L3H2 (8,5m3) / Thermo King V400X Max 20; L3H2 (8,5m3) / Thermo King V400X Max 50
Quantity: Default 1, Minimum 1 piece
Surcharge for automatic transmission
Optional · Suitable for: L2H2 (7,0m3) / Thermo King V300 max 20; L2H2 (7,0m3) / Thermo King V300 max 50; L2H2 (7,0m3) / Thermo King V300 max 50 Spectrum; L2H2 (7,0m3) / Thermo King V200 max 50; L2H2 (7,0m3) / Thermo King V200 max 20; L2H2 (7,0m3) / Thermo King V400X Max 20; L2H2 (7,0m3) / Thermo King V400X Max 50; L3H2 (8,5m3) / Thermo King V300-20; L3H2 (8,5m3) / Thermo King V200 max 50; L3H2 (8,5m3) / Thermo King V200 max 20; L3H2 (8,5m3) / Thermo King V400X Max 20; L3H2 (8,5m3) / Thermo King V400X Max 50
Quantity: Default 1, Minimum 1 piece
Partition in load compartment for multi-compartment solution
Optional · Suitable for: L2H2 (7,0m3) / CoolJet C206RC; L2H2 (7,0m3) / Thermo King V300 max 20; L2H2 (7,0m3) / Thermo King V300 max 50; L2H2 (7,0m3) / Thermo King V300 max 50 Spectrum; L2H2 (7,0m3) / Thermo King V200 max 50; L2H2 (7,0m3) / Thermo King V200 max 20; L2H2 (7,0m3) / Thermo King V400X Max 20; L2H2 (7,0m3) / Thermo King V400X Max 50; L3H2 (8,5m3) / Thermo King V300-20; L3H2 (8,5m3) / Thermo King V200 max 50; L3H2 (8,5m3) / Thermo King V200 max 20; L3H2 (8,5m3) / Thermo King V400X Max 20; L3H2 (8,5m3) / Thermo King V400X Max 50
Increased door-closing forces: Installing a partition increases the force required to close the doors and can lead to increased sliding-door wear over time. Please also note: If a fixed multi-compartment partition without a passage is installed in the load compartment, the German employers’ liability insurance association (BG) rules require a step at the sliding door, because the partition removes access to the front compartment through the rear doors. According to the BG, the customer may not enter the front compartment without a step and may only load and unload it from outside. Quantity: Default 1, Minimum 1 piece
Telescopic load restraint bar, 1 piece
Optional · Suitable for: L2H2 (7,0m3) / CoolJet C206RC; L2H2 (7,0m3) / Thermo King V300 max 20; L2H2 (7,0m3) / Thermo King V300 max 50; L2H2 (7,0m3) / Thermo King V300 max 50 Spectrum; L2H2 (7,0m3) / Thermo King V200 max 50; L2H2 (7,0m3) / Thermo King V200 max 20; L2H2 (7,0m3) / Thermo King V400X Max 20; L2H2 (7,0m3) / Thermo King V400X Max 50; L3H2 (8,5m3) / Thermo King V300-20; L3H2 (8,5m3) / Thermo King V200 max 50; L3H2 (8,5m3) / Thermo King V200 max 20; L3H2 (8,5m3) / Thermo King V400X Max 20; L3H2 (8,5m3) / Thermo King V400X Max 50
Transsafe load restraint bar, universally usable in all Airline rails Quantity: Default 1, Minimum 1 piece
Telescopic load restraint bar package, 2 pieces
Optional · Suitable for: L2H2 (7,0m3) / CoolJet C206RC; L2H2 (7,0m3) / Thermo King V300 max 20; L2H2 (7,0m3) / Thermo King V300 max 50; L2H2 (7,0m3) / Thermo King V300 max 50 Spectrum; L2H2 (7,0m3) / Thermo King V200 max 50; L2H2 (7,0m3) / Thermo King V200 max 20; L2H2 (7,0m3) / Thermo King V400X Max 20; L2H2 (7,0m3) / Thermo King V400X Max 50; L3H2 (8,5m3) / Thermo King V300-20; L3H2 (8,5m3) / Thermo King V200 max 50; L3H2 (8,5m3) / Thermo King V200 max 20; L3H2 (8,5m3) / Thermo King V400X Max 20; L3H2 (8,5m3) / Thermo King V400X Max 50
Transsafe load restraint bar, universally usable in all Airline rails Quantity: Default 1, Minimum 1 piece
Lashing strap package (2 straps)
Optional · Suitable for: L2H2 (7,0m3) / CoolJet C206RC; L2H2 (7,0m3) / Thermo King V300 max 20; L2H2 (7,0m3) / Thermo King V300 max 50; L2H2 (7,0m3) / Thermo King V300 max 50 Spectrum; L2H2 (7,0m3) / Thermo King V200 max 50; L2H2 (7,0m3) / Thermo King V200 max 20; L2H2 (7,0m3) / Thermo King V400X Max 20; L2H2 (7,0m3) / Thermo King V400X Max 50; L3H2 (8,5m3) / Thermo King V300-20; L3H2 (8,5m3) / Thermo King V200 max 50; L3H2 (8,5m3) / Thermo King V200 max 20; L3H2 (8,5m3) / Thermo King V400X Max 20; L3H2 (8,5m3) / Thermo King V400X Max 50
Quantity: Default 1, Minimum 1 piece
Euroscan RX3 temperature recorder with 2 sensors (available DIN slot required)
Optional · Suitable for: L2H2 (7.0m3) / CoolJet C206RC
The Euroscan RX3 is the proven solution for installation in the cab’s DIN radio slot. It is ideal for vehicles requiring a compact, robust system with an integrated printer. DIN slot format — easy installation without requiring additional space. Thermal transfer printer — maintenance-free and directly accessible to the driver. Up to 6 analogue probes — reliable sensing for established applications. Optional ColdChainView — integration via an external module. Technical specifications: Installation format: DIN radio slot (cab). Analogue probes: up to 6. Digital inputs: 4. Interfaces: 2× RS-232 · 1× CAN · 1× digital output. Printer: thermal transfer (maintenance-free). Communication: GSM / GPS via an external module (optional). Protection rating: IP20. Dimensions: 186 × 58 × 150 mm. Operating temperature: −30 °C to +70 °C. Certification: EN 12830:2018 · GAMP5 · GDP · HACCP · CE.
Euroscan RT8 RX 4G LTE temperature recorder with 2 sensors (available DIN slot required)
Optional · Suitable for: L2H2 (7.0m3) / CoolJet C206RC
DIN slot supplied by Kerstner if not fitted at the factory
Optional · Suitable for: L2H2 (7.0m3) / CoolJet C206RC; L2H2 (7.0m3) / Thermo King V300 max 20; L2H2 (7.0m3) / Thermo King V300 max 50; L2H2 (7.0m3) / Thermo King V300 max 50 Spectrum; L3H2 (8.5m3) / Thermo King V300-20
Position chosen at Kerstner’s discretion according to available cab space
Thermo King Touchlog Premium temperature recorder
Optional · Suitable for: L2H2 (7,0m3) / Thermo King V300 max 20; L2H2 (7,0m3) / Thermo King V300 max 50; L2H2 (7,0m3) / Thermo King V300 max 50 Spectrum; L2H2 (7,0m3) / Thermo King V200 max 50; L2H2 (7,0m3) / Thermo King V200 max 20; L2H2 (7,0m3) / Thermo King V400X Max 20; L3H2 (8,5m3) / Thermo King V300-20; L3H2 (8,5m3) / Thermo King V200 max 50; L3H2 (8,5m3) / Thermo King V200 max 20; L3H2 (8,5m3) / Thermo King V400X Max 20
Blue Box Lite including installation
Optional · Suitable for: L2H2 (7,0m3) / Thermo King V300 max 20; L2H2 (7,0m3) / Thermo King V300 max 50; L2H2 (7,0m3) / Thermo King V300 max 50 Spectrum; L2H2 (7,0m3) / Thermo King V200 max 50; L2H2 (7,0m3) / Thermo King V200 max 20; L2H2 (7,0m3) / Thermo King V400X Max 20; L3H2 (8,5m3) / Thermo King V300-20; L3H2 (8,5m3) / Thermo King V200 max 50; L3H2 (8,5m3) / Thermo King V200 max 20; L3H2 (8,5m3) / Thermo King V400X Max 20
Refrigeration unit cover painted in vehicle colour – solid –
Optional · Suitable for: L2H2 (7.0m3) / CoolJet C206RC
Refrigeration unit cover painted in vehicle colour – metallic –
Optional · Suitable for: L2H2 (7.0m3) / CoolJet C206RC